Регистрация
deal.by
094702 | CMS-R-AZA-05VL - фото 1 - id-p93676966
Характеристики и описание

Техническая спецификация в PDF  

Mechanical values and environment

DesignA
Material
Cable materialPVC
Housing materialFiber glass reinforced PPS
Weight
Net 0,26 kg
Ambient temperature -20 ... 60 °C
Degree of protectionIP67
Mechanical life 100 x 106
Installation positionAny, pay attention to marking During mounting it is to be ensured the marking arrows on actuator and read head are opposite each other.
Tightening torque 0,4 ... 0,5 Nm
Number of NO contacts2 NO contacts with fuse, 100 mA each and 1 NO contact with LED
ConnectionHard-wired encapsulated cable with cable end sleeves 0.34mm2
Cable length 5 m
Number of LED displays1 LED contact status indication
Method of operationMagnetic, reed contact

Electrical connection ratings

Rated conditional short-circuit current 100 A  Parameter dependent on the evaluation units ESM-BA2.. and ESM-BA3..
Fusing
Power supply / safety contacts, external contact protectionFuse 10 A gG Parameter dependent on the evaluation units ESM-BA2.. and ESM-BA3..
Switching voltage
Contact status indication24 ... 35 V
24 ... 35 V
Switching current
Contact status indicationmax.20 mA
max.100 mA
Switching characteristicsParallel
Switching voltage according to UL
According to UL Class 2AC/DCmax.24 V
Series resistance
LED contact status indication 1,5 k?
Switching frequency, electrical
At I_min = 10 mAmax.5 Hz  Parameter dependent on the evaluation units ESM-BA2.. and ESM-BA3..
At nominal current 8 A 0,1 Hz  Parameter dependent on the evaluation units ESM-BA2.. and ESM-BA3..
Switching delay from state change 26 ms  Parameter dependent on the evaluation units ESM-BA2.. and ESM-BA3..

Miscellaneous

in compliance withEN ISO 13849-1: 2015{} EN 62061: 2005 + AC: 2010 + A1: 2013 + Или отправьте нам запрос на13{} IEC 60947-5-3: 2013

Reliability values acc. to EN ISO 13849-1

Monitoring of the safety guard position
B10D 20 x 106

in combination withEvaluation unit ESM-BA201, ESM-BA202, ESM-BA203, ESM-BA301, ESM-BA302, ESM-BA303, ESM-BA201P, ESM-BA301PandActuator CMS-M-AI

Center offset
At s=3 mm read distance 2,5 mm  Figure only applies if there is no ferromagnetic material in the vicinity of the read head and the actuator.
Assured switch-off distance Sar
max.20 mm  The assured switch-off distance s_ar corresponds to the reset distance.
Contact status indication / LEDmax.15 mm  These values apply only in approach direction X, center offset m=0.
Assured operating distance Sao
With center offset m=0min.9 mm <
Был online: Давно
OOO "ФилФар Технолоджи"
Рейтинг не сформирован
10 лет на Deal.by

094702 | CMS-R-AZA-05VL

Под заказ
Цену уточняйте
Доставка
Оплата и гарантии